h2x User GuideUser Guide
๐Ÿ“ค Exports

Revit Export / Integration

The Revit Export lets you synchronize your h2x designs directly with Autodesk Revit.

It provides a seamless transition from h2x into a 3D model, prevents the need to draw it again, and ensures no details get missed between the design and calculation stage and drafting.

How to Install and Use the Revit Export Add-In

Step 1: Download and Install the Add-In

Step-by-step
  1. Download: Navigate to the Autodesk App Store to download the h2x Revit Sync add-in - https://apps.autodesk.com/RVT/en/Detail/Index?id=1861106365632198179&appLang=en&os=Win64

  2. Install: Run the downloaded installer and follow the instructions.

    Restart Revit after installation to activate the add-in.

Ensure compliance with your organization's IT and software requirements.

Step 2: Prepare Your h2x Design

Step-by-step
  1. Complete Design: Ensure all systems in your h2x project are finalized, including pipework, valves, equipment, etc.

  2. Check Results: Click the Results button in h2x to ensure all sizing calculations are accurate and up-to-date.

This is a one-way export, so it is important that you are happy with the h2x design before completing the export.

Step 3: Log In to Revit Add-in

Step-by-step
  1. Open Revit:

    Launch Revit and open the project file where you want to import your h2x design.

    Ensure that the project has the necessary levels and systems in place for aligning the imported systems.

  2. Access the h2x Sync Add-In:

    Navigate to the h2x Sync tab located in the Revit โ€˜Add-inโ€™ toolbar.

    If you donโ€™t see the tab, ensure that the h2x Revit add-in is installed correctly and restart Revit if needed.

    It may have been installed to a different version of Revit

  3. Log In:

    Click on the Login button in the h2x Sync tab.

    Enter your h2x account credentials.

If login fails, ensure you are using your h2x credentials and. verify your internet connection.

Step 4: Settings

Step-by-step
  1. General Tab

    Select Project: Use the drop-down menu to select the project you want to import into Revit.

    Troubleshooting: If your project is missing, log out of the h2x add-in, close Revit, and log back in.

    Save: Once selected, click Save to finalize your project selection.

  2. Alignment Tab

    Display h2x Base Point: Click Display h2x Base Point to show the crosshair that represents the alignment point from h2x .

    Use this point to align with a consistent reference that was used in h2x (e.g., a gridline like "1A").

    Align to Revit: In Revit, align the base point to the same reference point used in h2x for accurate placement.

    Hide Base Point and Save: After alignment, click Hide Base Point and Save.

    Troubleshooting: Use the alignment drop-down for additional troubleshooting tips.

  3. Systems Tab

    Mapping Systems: For each h2x system (e.g., hot water), choose a corresponding Revit system.

    This ensures the correct colors, naming conventions, and Revit properties are applied.

    Save: Save mappings after completion.

  4. Pipe Materials Tab

    Map Materials: For example, match Copper (h2x) to Copper (Revit) for correct material representation.

    Save: Save mappings after completion.

  5. Levels Tab

    Link Levels: Match levels in h2x (e.g., Level 1 , Level 2) to Revit levels (e.g., Level 1, Level 2).

    Save: Save mappings after completion.

  6. Valves Tab

    Mapping Valves: For example, link Balancing Valve (h2x) to a corresponding valve family in Revit.

    Save: Save mappings after completion.

The Settings section is the foundation of the h2x-to-Revit workflow, allowing precise mapping, alignment, and customization to ensure compatibility between your designs and Revit.

Step 5: Sync Process

Step-by-step
  1. Preview (Check Green Ticks):

    Ensure that all sections (systems, materials, levels) have green ticks.

    If any section is incomplete, click on it to complete the mapping.

  2. Mapping Warnings:

    Levels: Unmapped levels wonโ€™t be imported into Revit.

    Systems or Materials: Unmapped items will not appear in the Revit model.

    Return to the Settings tab to map the missing elements or acknowledge and proceed if intentional.

  3. Sync:

    Click Sync to begin the process.

    The time required depends on the project size.

    Errors like โ€œinsufficient space for fittingsโ€ may appear.

    Click Delete Element to remove the fitting.

    These errors donโ€™t affect other parts of the design.

  4. Project Synced:

    Open the design and verify that all components, levels, and systems are correctly imported.

    Click on individual components to review calculation details imported from H2X.

Issues with the Revit Add-In

Issues Logging into h2x Sync in Revit

If you're having trouble logging into h2x Sync in Revit, follow these steps.

Step-by-step
  1. Disable PyRevit or Bluebeam:

    Fully disable PyRevit or Bluebeam before running the h2x add-in, as these programs can interfere with our functionality.

  2. Adjust Project Information:

    Make a small change to the Project Information in Revit. Sometimes this resolves issues related to the add-in functionality.

    Go to the Manage tab on the Revit ribbon.

    Click Project Information from the Project Settings panel.

    In the dialog box, locate any field such as Project Name, Client Name, or Project Number.

  3. Check Firewall Settings:

    Ensure your companyโ€™s firewall isnโ€™t blocking access to h2x.

    To verify, try accessing the h2x website via your browser. If the website loads, your firewall settings are likely fine.

  4. Reinstall the Add-In:

    Uninstall your current version of the h2x add-in.

    Download and install the latest version from this official site.

    Ensure it is installed for the correct Revit version

Resolving Add-In Conflict Errors

If you receive an error when opening h2x in Revit due to conflicts with other add-ins, follow these steps to resolve it:

Step-by-step
  1. Download DiRoots App Manager:

    Use the DiRoots App Manager to manage and disable conflicting add-ins.

  2. Disable Conflicting Add-Ins:

    Open the DiRoots App Manager.

    Navigate to the Add-In Manager tab.

    Disable all add-ins except for h2x.

  3. Restart Revit:

    Close and reopen Revit to apply the changes.

Project Base Point Not Displayed

If the Project Base Point isnโ€™t visible in your current view, follow these steps:

Step-by-step
  1. Switch to a Different View:

    Open a 3D view or a different 2D view before clicking Display Project Base Point in h2x Sync.

  2. Check Visibility and Graphics Settings:

    Ensure the h2x Project Base Point is enabled in Revitโ€™s Visibility and Graphics Settings.

    Verify that Lines Categories are also enabled in the same settings.

  3. Use DiRoots App Manager:

    Close Revit.

    Open the DiRoots App Manager.

    Navigate to the Add-In Manager tab and disable all add-ins except for H2X.

    Relaunch Revit and retry displaying the project base point.